2013年10月3日星期四

Riverbed 201-01 exam pdf dumps

Those who want to prepare for the IT certification exam are helpless. But they have to do it. So they have restless state of mind. However, With IT-Tests.com Riverbed 201-01 exam training materials, the kind of mentality will disappear. With IT-Tests.com's Riverbed 201-01 exam training materials, you can be brimming with confidence, and do not need to worry the exam. Of course, you can also face the exam with ease. This is not only psychological help, but more importantly, it allows you to pass the exam and to help you get a better tomorrow.

There is no site can compare with IT-Tests.com site's training materials. This is unprecedented true and accurate test materials. To help each candidate to pass the exam, our IT elite team explore the real exam constantly. I can say without hesitation that this is definitely a targeted training material. The IT-Tests.com's website is not only true, but the price of materials are very reasonable. When you choose our products, we also provide one year of free updates. This allow you to have more ample time to prepare for the exam. So that you can eliminate your psychological tension of exam, and reach a satisfactory way.

Exam Code: 201-01
Exam Name: Riverbed (Riverbed Certified Solutions Associate - Network Performance Management)
Free One year updates to match real exam scenarios, 100% pass and refund Warranty.
Total Q&A: 195 Questions and Answers
Last Update: 2013-10-03

IT-Tests.com has a huge IT industry elite team. They all have high authority in the IT area. They use professional knowledge and experience to provide training materials for people ready to participate in different IT certification exams. The accuracy rate of exam practice questions and answers provided by IT-Tests.com is very high and they can 100% guarantee you pass the exam successfully for one time. Besides, we will provide you a free one-year update service.

If you do not know how to pass the exam more effectively, I'll give you a suggestion is to choose a good training site. This can play a multiplier effect. IT-Tests.com site has always been committed to provide candidates with a real Riverbed 201-01 certification exam training materials. The IT-Tests.com Riverbed 201-01 Certification Exam software are authorized products by vendors, it is wide coverage, and can save you a lot of time and effort.

201-01 (Riverbed Certified Solutions Associate - Network Performance Management) Free Demo Download: http://www.it-tests.com/201-01.html

NO.1 Some common protocols, which may be observed on a network with visibility tools, include:
A. HTTP over TCP/80 and HTTPS over TCP/445
B. HTTP over TCP/80 and HTTPS over TCP/443
C. HTTP over TCP/443 and HTTPS over TCP/80
D. HTTP over TCP/445 and HTTPS over TCP/80
E. HTTP over TCP/88 and HTTP over TCP/444
Answer: B

Riverbed demo   201-01 exam prep   201-01   201-01 demo   201-01 dumps

NO.2 How does the Cascade Profiler determine the optimization levels achieved for WAN Optimization
reports?
A. Compare the amount of traffic crossing a LAN interface to the corresponding traffic crossing an
optimized WAN interface.
B. Compare updates received via SNMP from Steelhead optimization devices with router devices.
C. The Cascade Profiler cannot determine optimization levels.
D. Through manual entry of levels achieved.
E. Compare updates received via flows from Steelhead optimization devices with router devices.
Answer: A

Riverbed   201-01 braindump   201-01 braindump

NO.3 In a Cascade deployment with Sensor and Profiler, what information does the Application Performance
Policy report show? (Select 4)
A. Number of connections per second
B. Average Response time
C. TCP resets
D. CPU and memory utilization of server
E. TCP retransmission
F. Number of jumbo frames
Answer: A,B,C,E

Riverbed practice test   201-01   201-01 test

NO.4 What is the minimum number of physical boxes involved in a Cascade Enterprise Profiler?
A. 1
B. 2
C. 3
D. 4
E. 5
Answer: C

Riverbed braindump   201-01 study guide   201-01 practice test   201-01   201-01 exam prep

NO.5 In the Cascade Profiler GUI, what do the QoS values mean?
A. They are based upon the 6-bit Differentiated Services Code Point (DSCP).
B. They are based upon Host Group definitions, defined within the Cascade GUI.
C. They are based upon Application definitions, defined within the Cascade GUI.
D. They are based upon Port definitions, defined within the Cascade GUI.
Answer: A

Riverbed exam prep   201-01 dumps   201-01 study guide   201-01 certification   201-01

NO.6 To drill down and analyze a file within Cascade Pilot, you should. (Select 2)
A. Select a graphic object in a View chart, and drag a View on the object.
B. Select a graphic object in a View chart, and drag a View on the trace file.
C. Select the View, right-click, and apply it with the filter associated with a graphic object.
D. Right-click in the View chart, and select "Drill-down" to select the View.
Answer: A,D

Riverbed   201-01   201-01 dumps   201-01 pdf   201-01 test answers

NO.7 On Cascade Profiler, which of the following are configurable from the Configuration> User Interface
Preferences interface? (Select 4)
A. Default Host Group Type to use on the User Interface and Reports
B. Whether hosts will be displayed by IP address or DNS/DHCP hostname
C. User ¯s Timezone to use for the User Interface and Reports
D. Option to control whether bandwidth is reported in Bits or Bytes
E. Host group definitions for mapping IP subnets into Custom host groups
Answer: A,B,C,D

Riverbed   201-01   201-01 answers real questions   201-01

NO.8 How do you configure a new user for the Cascade Shark appliance?
A. From the User Management section of the Web Interface
B. From the Basic Settings page of the Web Interface
C. From the Users menu of Cascade Pilot
D. From the Advanced Settings page of the Web Interface
Answer: A

Riverbed   201-01 exam   201-01   201-01   201-01 certification

NO.9 Which of the following supports the largest number of Cascade analytics?
A. Express
B. Standard Profiler
C. Enterprise Profiler
D. B and C
E. A, B, and C
Answer: C

Riverbed braindump   201-01   201-01

NO.10 What are the default credentials to log into the Cascade Shark appliance Web Interface?
A. admin/admin
B. root/sharkappliance
C. root/root
D. root/riverbed
E. admin/cacetech
Answer: A

Riverbed   201-01 practice test   201-01 exam dumps

NO.11 Outgoing Mail Server (SMTP) Settings enable Cascade Profiler to: (Select 2)
A. receive mail from others.
B. send reports.
C. send disk failure notifications.
D. send alerts.
Answer: B,D

Riverbed test   201-01 test   201-01   201-01 dumps

NO.12 What are the ways Cascade Profiler can graphically depict response times in the GUI?
A. In Overall Traffic Graphs
B. In Connection Graphs
C. In Dashboard Line Graphs
D. In Overall Traffic Graphs and in Connection Graphs
Answer: D

Riverbed dumps   201-01   201-01   201-01

NO.13 What are some reports Cascade Profiler provides to benefit WAN management?
A. WAN Optimization Benefits reports, Breakdown of business versus non-business application reports,
QOS reports by interface and/or application.
B. WAN Optimization of all TCP protocols with more specific optimization of over 50 TCP Applications.
C. WAN reporting of TCP Protocols.
D. QOS shaping, User-based policies that will block not compliant traffic, WAN optimization reporting.
Answer: A

Riverbed test answers   201-01   201-01 exam   201-01 questions   201-01

NO.14 Configuring the Cascade appliance to use RADIUS for authentication/authorization involves which of
the following tasks (in no particular order): (Select 4)
A. User Name
B. Specify the IP address of the RADIUS server
C. Port number
D. Password
E. Authentication protocol
F. Shared secret of each RADIUS server
Answer: B,C,E,F

Riverbed   201-01 demo   201-01   201-01 exam prep   201-01 dumps   201-01

NO.15 If one has a Service Health dashboard widget included on a dashboard, will all newly created Services
automatically appear on that dashboard widget?
A. Yes, always.
B. It depends on whether all of the segments initialize their baseline.
C. It depends on what criteria was used when defining the dashboard widget.
D. It depends on which user defined and committed the Service.
E. It depends on how many Services have already been configured.
Answer: C

Riverbed   201-01   201-01   201-01 exam dumps

NO.16 Which of the following are differences between the Cascade Sensor and the Cascade Shark appliances?
(Select 2)
A. Cascade Shark appliance can monitor 10GE interface traffic but Cascade Sensor cannot.
B. Cascade Sensor can provide flow data to Cascade Profiler but Cascade Shark appliance cannot.
C. Cascade Shark appliance has much higher write-to-disk rates than the Cascade Sensor and is the
appropriate appliance when packet capture is the primary requirement.
D. Cascade Sensor can recognize the application type by its DPI signature database but Cascade Shark
appliance cannot.
Answer: C,D

Riverbed answers real questions   201-01 exam prep   201-01

NO.17 In the Cascade Profiler GUI, what format can be used for a Dashboard Content Block? (Select 3)
A. Connection Graph
B. Detailed Flow List
C. Table
D. Pie Chart
E. Line Graph
Answer: C,D,E

Riverbed study guide   201-01 exam prep   201-01   201-01

NO.18 Within Cascade Pilot, how are views used to analyze a trace file? (Select 2)
A. Drag the trace file on the View to apply the View.
B. Right-click the View item and select "Apply with Filter".
C. Drag a View on the trace file to apply the selected View.
D. Select the View and the trace file, and double-click the trace file.
Answer: B,C

Riverbed   201-01 practice test   201-01 exam prep

NO.19 What are the types of content blocks available to view Events
on the Cascade Profiler dashboard?
(Select 2)
A. Security Events
B. Performance and Availability Events
C. Current Events
D. Unacknowledged Events
E. Public Events
F. Private Events
G. Per User Events
H. Per IP Address Events
Answer: C,D

Riverbed exam   201-01   201-01

NO.20 To organize hosts into logical arrangements what is important to configure on Cascade Profiler.?
A. Host Baseline Profiles
B. Custom Port Definitions
C. Host Groupings
D. Mitigation Configuration
Answer: C

Riverbed exam   201-01 certification   201-01 demo   201-01   201-01 answers real questions

IT-Tests.com offer the latest HP0-J62 Questions & Answers and high-quality HP2-B25 PDF Practice Test. Our 1Z0-027 VCE testing engine and 70-463 study guide can help you pass the real exam. High-quality C_THR12_66 Real Exam Questions can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.

Article Link: http://www.it-tests.com/201-01.html

没有评论:

发表评论